5.4.4 Pre-filter Maintenance

The pre-filter requires regular maintenance. Every 30 days,
or more frequently if the flow of oil slows, remove the cap
and clean the attached screen.
1. Wearing protective gloves use the supplied wrench to
remove the cap from the pre-filter (Figure 1).
2. Use a small brush to clear debris from the attached
screen (Figure 2).
3. Clean under a water tap and thoroughly dry.
4. Return the cap to the pre-filter housing and tighten.
DO NOT remove the pre-filter cap when a filter cycle is under way. DO NOT operate the filter system
with the cap removed. Wear protective gloves when handling the cap. The metal and the exposed oil are
hot.
5.5

BI-MONTHLY CHECKS AND SERVICE

5.5.1 Cleaning the Oil Saddle Reservoir

Every 2 months completely drain the oil saddle.
1. Disconnect the quick disconnect on the bottom of the oil saddle reservoir.
2. Pour the excess oil saddle oil into a frypot.
3. Reconnect the quick disconnect.
4. Fill with oil.
5.6

QUARTERLY CHECKS AND SERVICE

5.6.1 Replace the O-rings
Refer to page 4-2 for inspection of O-rings.