Assembling The Water Heater Stand; Floor Mounting The Water Heater; Installing The Exhaust Pipe Clamp And Condensate Trap - Westinghouse WGRGH20**75F Series Installation, Start-Up, Maintenance, Parts, Warranty

Residential gas hybrid water heaters
Table of Contents

Advertisement

16

1. Assembling the Water Heater Stand

NOTE: Ensure the Water Heater Stand Assembly has shipped with all
included components. See Figure 5.
Figure 5 - Water Heater Stand and Components
1.
Use a 5/16" socket and two (2) carriage bolts and nuts to connect
a cross beam to two legs. See Figure 6, Step 1.
2.
Use a 5/16" socket and two (2) carriage bolts and nuts to connect
a cross beam to the other legs. See Figure 6, Step 2.
3.
Lower the assembled stand onto the feet. See Figure 6, Step 3.
4.
After the stand is assembled, it is highly recommended that two
people lift and gently lower the water heater onto the water
heater stand. See Figure 7.
Figure 6 - Assembling the Water Heater Stand

2. Floor Mounting the Water Heater

For Installations in the State of California
For installation in California this water heater must be braced or
anchored to avoid falling or moving during an earthquake. See
instructions for correct installation procedures. Instructions may be
obtained from California Office of the State Architect, 1102 Q Street,
Suite 5100, Sacramento, CA 95811.
whl-605 Rev. 002 Rel. 000 Date 1.23.19

3. Installing the Exhaust Pipe Clamp and Condensate Trap

The factory supplied water heater stand and condensate trap
must be installed with the water heater. Failure to properly install
condensate trap will allow dangerous gas to contaminate the
structure and result in property damage, serious personal injury,
or death. DO NOT operate the water heater for any amount of time
for any reason until the condensate trap is installed.
1.
Insert the Condensate Trap into the Exhaust Adaptor. Install the
Condensate Trap Clamp to hold it in place.
2.
Place the exhaust pipe inside the Exhaust Adaptor. While
holding the exhaust pipe in place, attach the pipe clamp to the
pipe support with a screw driver and two (2) M5 screws.
Pipe Support
Pipe Clamp
Screw M5 : 2pcs
Exhaust Adaptor
APS Tube
Trap Clamp
Condensate Trap
Water Heater Stand
Figure 7 - Installing the Water Heater Exhaust Pipe Clamp, Condensate
Trap, and Setting the Water Heater on the Stand
Exhaust Chamber