S.4.3 Run command source selection
Key operation to set A002
****FF3 : Change from 02 (operator) to 01 (control circuit terminal block).
Procedure
Key operation
2-1
2-2
1
2-3
2-4
2-5
2-6
2-7
2-8
2-9
****FEF3/FUF3 : Change 01 (control circuit terminal block) to 02 (operator).
*) Replace the procedure 2-6 and 2-7 on the list above with 2-6' and 2-7' in the list below.
Procedure
Key operation
2-6'
2-7'
Indication
.

FUNC

2
or

FUNC

1

FUNC

2

STR
.
FUNC
Indication

FUNC

1
Start-up
After powering up of the inverter, the operator displays
0.00, output frequency monitor (d001)
Indication changes from data (0.00) to parameter (d001).
Push the key and select the head of Group A.
Push the key and indication changes to A001.
Push the key and select A002 (Run command source).
Push the key and indication changes to 02(operator).
Push the key and change the data to 01 (control circuit
terminal block).
Push the key and indication changes to A002 (Data save).
By pushing the key for more than three seconds,
indication changes to the output frequency data.
(It depends on b038 setting)
Push the key and indication changes to 01 (control circuit
terminal block).
Push the key and change to 02(operator).