Table Inspection Of Outdoor Unit Main Parts - Toshiba RAV-GP561ATP-E Service Manual

Air-conditioner (split type), outdoor unit
Hide thumbs Also See for RAV-GP561ATP-E:
Table of Contents

Advertisement

8-3. Table Inspection of outdoor unit main parts

No.
Parts name
1
Compressor
(Model : DA150A1T-21F)
2
Fan motor
(Model : ICF-140-A43-1)
Measure the resistance value of each winding by using the tester.
Red
White
Black
Measure the resistance value of each winding by using the tester.
Red
White
Black
- 63 -
Checking procedure
Position
Red – White
White – Black
Black – Red
Position
Red – White
White – Black
Black – Red
FILE NO. SVM-18041
Resistance value
0.93 Ω
Under 20°C
Resistance value
21.00±1.05 Ω
Under 20°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-gp561atp-trRav-gp561atjp-e

Table of Contents