Heatilator CALIBER DESIGNER B-VENT SERIES Installation And Operating Instructions Manual page 16

Hide thumbs Also See for CALIBER DESIGNER B-VENT SERIES:
Table of Contents

Advertisement

2. Standing Pilot Ignition Appliances
FOR YOUR SAFETY READ BEFORE LIGHTING THE STANDING PILOT
A.
This appliance has a manual ignition device that
lights the pilot. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
1.
Turn off wall switch.
2. Open control access panel.
3. Turn gas line to “CLOSED”. Wait 5 minutes to clear out
any gas. Then smell for gas, including near the floor. If
you smell gas, STOP! Follow “B” in the safety information
above on this label. If you don’t smell gas, go to the next
step.
4. Turn gas line to “OPEN”.
5. Turn pilot knob clockwise to “OFF”. Knob may have t o
be depressed to pass the “PILOT” position.
6. Locate pilot assembly inside appliance.
7. Locate red ignitor button.
8. Turn pilot knob to “PILOT” and push in.
9.
Continue to hold in pilot knob and push the red ignitor
button 12-15 times until small blue pilot flame appears.
10. Continue to hold in pilot knob for approximately one minute.
Pilot should remain lit. If pilot goes out, wait 5 minutes and
repeat Steps 4-9.
11. Release and turn the knob counterclockwise to “ON”. To
light the main burner, turn the wall switch to “ON”. Do not
light by hand.
12. If the appliance will not operate, follow the instructions
“To Turn Off Gas To Appliance” and call your service
Note:
To light main burner, turn the Wall Switch to
“ON”. Do not light by hand.
16
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the supplier’s
instructions.
LIGHTING INSTRUCTIONS
STOP! Read the safety information above on this label!
WARNING!
C. Use only your hand to push in or turn knob. Never
use tools. If the knob will not push in or turn by
hand, don’t try to repair it; call a qualified service
technician. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system and any gas control
which as been under water.
TO TURN OFF THE GAS TO THE APPLIANCE
1.
Turn off the wall switch.
2.
Open the control access panel.
3.
Turn the gas line to CLOSED position. Do not force.
4.
Close the control access panel.
33795 Rev i
CALIBER DESIGNER SERIES
If you cannot reach your gas supplier, call
the fire department.
01/04

Advertisement

Table of Contents
loading