Product Overview

Product Overview

ESP-880A

Front Panel

LED Indicators:
q
Power:
Power or fault state indication.
Signal:
Signal status indication of all audio input
and output channels in order of signaling
priority. For precise metering and gain
control, connect using ControlSpace
Designer software.
Ethernet: Connection status indication of Ethernet
ports.
Serial:
Serial command status indication for
CC-16 zone controller or RS-232 device.

Rear Panel

q
Audio Inputs & Outputs: Mic-/line-level inputs and line-level outputs balanced analog audio signals.
q
See 4. Connecting Analog Audio Devices (page 18) for more information.
AmpLink Out port: Ethernet connection for use with AmpLink-equipped PowerMatch amplifiers.
w
See 5. Connecting ControlCenter, AmpLink & Serial Control Devices (page 18) for more information.
Serial number.
e
RS-232 port: Five-wire, RS-232 (DTE) serial interface connection.
r
Power input: Power cord connection (IEC 60320-C14 inlet).
t
Network port: Ethernet network connection for up to 15 ControlCenter interfaces.
y
See 5. Connecting ControlCenter, AmpLink & Serial Control Devices (page 18) for more information.
CC-16 connector: RS-485 network connection for up to 15 CC-16 zone controllers.
u
See 5. Connecting ControlCenter, AmpLink & Serial Control Devices (page 18) for more information.
Control Inputs & Outputs: Five inputs and five outputs for general-purpose control. See 7. Connecting
i
GPIO Devices (page 20) for more information.
12 • English
q
Green: Power on, normal operation
Yellow: Powering on
Red: Error (see Troubleshooting on page 22)
Green: Signal present (–60 dBFS to –20 dBFS)
Yellow: Signal level optimal (–20 dBFS to –2 dBFS)
Red: Clipping (–2 dBFS to 0 dBFS)
Green: Ethernet link established
Yellow: Active transmission/reception
Green: CC-16 controller command transmitted
Yellow: CC-16 controller command received
Red: Active RS-232 transmission/reception
q
i
w
ControlSpace ESP-880A/880AD/1240A/1240AD • Installation Guide