Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110
volts. Maximum length of 20 feet of 16 AWG to conductor wires is
to be used with all optional switches.
Use the two leads (Red and Green) to attach optional components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked with
a millivolt meter 0-1000 MV range.
THERMOPILE
PILOT
VEILLEUSE
THERMOCOUPLE
(NATURAL)
Keep the control compartment, logs and burner area surrounding
the logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the rating plate of the log set.
39236-1-0219
WIRING DIAGRAM
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
THERMOCOUPLE
(LPG)

MAINTENANCE

WIRING

Remote Receiver
Use the following steps to place optional remote receiver adjacent
to the gas valve.
1.
The remote receiver can not be placed behind the gas valve
or burner assembly.
2.
When facing the appliance, the remote receiver must be placed
to the right or left side of the gas valve.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for
more details on remote control.
H
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
REMOTE
OFF
ON
GAS VALVE
Figure 32
Never obstruct the flow of the combustion and ventilation air. Keep
the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.
Screen should be closed during operation.
REMOTE CONTROL RECEIVER/
THERMOSTAT/CONTROLE E
DISTANCE DU RECEPTEUR
N
GAS VALVE
VALVE DE GAZ
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
o
150C DU L'EQUIVALENT.