MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
A. This appliance has a pilot which must be lit by hand. When
lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
1. STOP! Read the safety information label.
2. Remove barrier assembly.
3. Set REMOTE/OFF/ON switch to
"OFF."
4. Turn off all electric power to the
appliance (if applicable).
5. Push in gas control knob slightly
and turn clockwise
"OFF." NOTE: Knob cannot be
turned from "PILOT" to "OFF" unless knob
is pushed in slightly. Do not force.
6. Wait ten (10) minutes to clear out any gas.
Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety
information above. If you do not
smell gas, go to the next step.
7. Find pilot - Follow metal tube
from gas control. The pilot is
behind the burner on the right
side.
1. Remove barrier assembly.
2. Set REMOTE/OFF/ON switch to "OFF."
3. Turn off all electric power to the appliance if service is
to be performed (if applicable).
39236-1-0219
LIGHTING INSTRUCTIONS
GAS CONTROL KNOB
GAS CONTROL KNOB
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
SHOWN IN "OFF" POSITION.
to
SHOWN IN "OFF" POSITION.
REMOTE
REMOTE
REMOTE
OFF
OFF
OFF
ON
ON
ON
PILOT
PILOT
PILOT
THERMOPILE
THERMOPILE
THERMOPILE
ELECTRODE
ELECTRODE
ELECTRODE
THERMOCOUPLE
THERMOCOUPLE
THERMOCOUPLE
(LPG)
(LPG)
(LPG)
THERMOCOUPLE
THERMOCOUPLE
THERMOCOUPLE
(NATURAL)
(NATURAL)
(NATURAL)
TO TURN OFF GAS TO APPLIANCE
WARNING
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it; call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
8. Turn gas control knob counterclockwise
"PILOT."
9. Push in control knob all the way and hold in. Repeat-
edly push the Piezo Ignitor Button until the pilot is lit.
Continue to hold the control knob in for about one (1)
minute after the pilot is lit. Release knob, and it will
pop back up. Pilot should remain lit. If it goes out,
repeat steps 5 through 9.
If knob does not pop up when released, STOP and
IMMEDIATELY call a qualified service technician
or gas supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your ser-
vice technician or gas supplier.
10. Turn gas control knob counterclockwise
"ON."
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turn on all electric power to the appliance (if appli-
cable).
13. Re-install the barrier assembly.
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Re-install the barrier assembly.