Problem solving guide
Replacing the angled
connector
If instead of being frothed the milk is
only being heated up, check the
following first:
– Is the milk in the milk flask cold
(< 10 ° C)?
– Have the central spout and the milk
flask lid been cleaned carefully?
– Is the central spout correctly fitted?
If after checking the above, milk still
cannot be frothed, replace the angled
connector as follows:
You will need the replacement angled
connector supplied with the coffee
machine.
Do not use a needle or similar
implement. This would damage the
components.
Open the maintenance panel on the
back of the machine front.
90
First release air intake tube from
opening . Then pull off angled
connector .
Pull both tubes out of the angled
connector.
Clean air intake tube under running
water with the cleaning brush
supplied. "Blowing through" can help
to dislodge blockages.
Insert the brush in milk tube . Move
the brush back and forth as far as
possible until all milk deposits have
been removed.
Take the new angled connector. (You
can dispose of the old angled
connector with normal household
waste).