Mitsubishi Electric MXZ-8B48NA Technical & Service Manual page 74

Hfc utilized r410a, split-type, heat pump air conditioners, outdoor unit, branch box
Hide thumbs Also See for MXZ-8B48NA:
Table of Contents

Advertisement

SW2 setting
Indoor pipe temperature / Liquid
TH2
ON
Indoor-B
– 35~88 (°C)
1
2 3 4 5 6
– 31~190 (°F)w
Indoor pipe temperature / Liquid
TH2
ON
Indoor-C
– 39~88 (°C)
1
2 3 4 5 6
– 38~190 (°F)w
Indoor pipe temperature / Liquid
TH2
ON
Indoor-D
– 39~88 (°C)
1
2 3 4 5 6
– 38~190 (°F)w
Indoor pipe temperature / Liquid
TH2
ON
Indoor-E
– 39~88 (°C)
1
2 3 4 5 6
– 38~190 (°F)w
LEV-1 opening pulse
ON
0~500
1
2 3 4 5 6
LEV-2 opening pulse
ON
0~500
1
2 3 4 5 6
LEV-3 opening pulse
ON
0~500
1
2 3 4 5 6
LEV-4 opening pulse
ON
0~500
1
2 3 4 5 6
LEV-5 opening pulse
ON
0~500
1
2 3 4 5 6
Outdoor pipe temperature / 2-phase
(TH6)
ON
– 39~88 (°C)
– 38~190 (°F)w
1
2 3 4 5 6
Outdoor outside temperature (TH7)
– 39~88 (°C)
ON
– 38~190 (°F)w
1
2 3 4 5 6
w SW1-8 : OFF (Unit: °C), SW1-8 : ON (Unit: °F)
Display detail
Explanation for display
– 35~88 (°C), – 31~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
0~500
0~500
0~500
0~500
0~500
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
74
Unit
°C
°F(w)
°C
°F(w)
°C
°F(w)
°C
°F(w)
Pulse
Pulse
Pulse
Pulse
Pulse
°C
°F(w)
°C
°F(w)