Mitsubishi Electric MXZ-8B48NA Technical & Service Manual page 10

Hfc utilized r410a, split-type, heat pump air conditioners, outdoor unit, branch box
Hide thumbs Also See for MXZ-8B48NA:
Table of Contents

Advertisement

• Branch box : PAC-AKA51BC PAC-AKA31BC
Model name
Connectable number of indoor units
Power supply (from outdoor unit)
Input
Running current
External finish
Drain hose size (on site)
Width
Dimensions
Depth
Height
Weight
Piping
Branch (indoor side)
connection
(Flare)
Main (outdoor side)
To indoor unit
Wiring
To outdoor unit
W The piping connection size differs according to the type and capacity of indoor units. Match the piping connection size for indoor
and branch box. If the piping connection size of branch box does not match the piping connection size of indoor units, use
optional different-diameter (deformed) joints to the branch box side. (Connect deformed joint directly to the branch box side.)
kW
A
mm (in.)
mm (in.)
mm (in.)
mm (in.)
kg (lbs)
mm (in.)
Liquid
Gas
mm (in.)
Liquid
mm (in.)
Gas
mm (in.)
10
PAC-AKA51BC
MAX. 5
Single phase, 208/230V, 60Hz
0.003
0.05
Galvanized sheets
O.D.20 (O.D. 3/4)
450 (17 - 3/4)
280 (11)
198 (7 - 3/4)
9.6 (21)
6.35 (1/4) × 5 {A,B,C,D,E}
9.52 (3/8) × 4 {A,B,C,D},
12.7 (1/2) × 1{E}
9.52 (3/8)
15.88 (5/8)
Each 3-wire, plus earth wire
3-wire, plus earth wire
PAC-AKA31BC
MAX. 3
8.4 (19)
6.35 (1/4) × 3 {A,B,C}
9.52 (3/8) × 3 {A,B,C}