Mitsubishi Electric MXZ-8B48NA Technical & Service Manual page 73

Hfc utilized r410a, split-type, heat pump air conditioners, outdoor unit, branch box
Hide thumbs Also See for MXZ-8B48NA:
Table of Contents

Advertisement

SW2 setting
LEV-B opening pulse
0~500
ON
1
2 3 4 5 6
LEV-C opening pulse
0~500
ON
1
2 3 4 5 6
LEV-D opening pulse
0~500
ON
1
2 3 4 5 6
LEV-E opening pulse
0~500
ON
1
2 3 4 5 6
Capacity setting indoor-A
ON
1
2 3 4 5 6
Capacity setting indoor-B
ON
1
2 3 4 5 6
Capacity setting indoor-C
ON
1
2 3 4 5 6
Capacity setting indoor-D
ON
1
2 3 4 5 6
Capacity setting indoor-E
ON
1
2 3 4 5 6
Indoor pipe temperature / Liquid
TH2
ON
Indoor-A
– 39~88 (°C)
1
2 3 4 5 6
– 38~190 (°F)w
w SW1-8 : OFF (Unit: °C), SW1-8 : ON (Unit: °F)
Display detail
73
Explanation for display
0~500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 150 pulse; 0.5 secs.
1
0~500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 150 pulse; 0.5 secs.
1
0~500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 150 pulse; 0.5 secs.
1
0~500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example)
When 150 pulse; 0.5 secs.
1
Code display
(Not Qj)
2
3
6
8
9
11
– 39~88 (°C), – 38~190 (°F)
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
Unit
Pulse
0.5secs.
2 secs.
50
Pulse
0.5secs.
2 secs.
50
Pulse
0.5secs.
2 secs.
50
Pulse
0.5secs.
2 secs.
50
Code
display
Rated
Code
capacity
display
06
09
Code
display
12
15
Code
display
17, 18
24
Code
display
°F(w)
°C