Band Power

A band power measurement using the markers calculates the average
power between two adjustable markers. To make a band power
measurement:
Press the
key.
Marker
Press
,
Trace
Spectrum
spectrum signal. Press the
the average spectrum trace.
Press
Function, Band Power
Two marker lines are activated at the extreme left side of the
horizontal scale. Press
place by rotating the
Press
to bring marker 2 to the same place as marker 1.
Delta
Move marker 1 to the other desired position by rotating the
knob. Band power measures the average power between the two
markers. When the band power markers are active, the results are
shown in the results window as Mean Pwr (Between Mks). When the
band power function is off the results window reads Mean Pwr
(Entire Trace).

Troubleshooting Hints

Changes made by the user to advanced spectrum settings, particularly
to ADC range settings, can inadvertently result in spectrum
measurements that are invalid and cause error messages to appear.
Care needs to be taken when using advanced features.