SIA Feature Programming
Comments
Section
Exit Time
Access to Entry and Exit delays and Bell Time Out for the system.
[005]>[001], option 3
Exit Delay Restart
Opening a Delay zone door after it has already been opened and closed during an exit delay restarts the
exit delay timer.
[018], option 7
Auto Stay Arm on Un-vacated
Function key: Forces the system to arm in Stay mode if the occupant does not exit the premises after
Premises
pressing the Away function key.
[001]>[001]-[128] Zone type 05,
06,09
Exit
Time
and
Progress
System times and audible exit beeps can be disabled when using the wireless key to stay arm the system.
Annunciation/Disable or Remote
When away arming, audible exit beeps can not be disabled.
Arming
[861]>[001]-[005], option 4
Entry delay(s)
Access to entry and exit delays and bell time out for the system
[005]>[001]-[008], options 1 and 2
Note: Combined entry delay and communications delay (abort window) shall not exceed 60s.
Abort Window for Non-Fire zones
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone. May be disabled by
zone or zone type.
[002]>[001]-[128], option 7 ON
Abort Window Time - for Non-
Access to the programmable delay before communicating alarms
Fire zones
Note: Combined entry delay and communications delay (abort window) shall not exceed 60 seconds.
[377]>[002], option 1
Abort Annunciation
An audible tone is generated when an alarm is aborted during the abort window.
Duress Feature
When this feature is enabled, selected user codes send a duress reporting code to the central station when
used to perform any function on the system. Section [019], option [6] must be enabled.
[*][5]> master code> user 2-95> 5>
2
Cancel Window
Access to the communications cancel window. Minimum duration must be 5 minutes.
[377]>[002], option 6
Cancel Annunciation
Access to the reporting code for Alarm Canceled.
[308]>[001], option 8
Cross Zoning
Enables cross zoning for entire system. Zones can be enabled for cross zoning via zone attribute option
8 in sections [002][101] - [128].
[042]>Selection 3, option 002
Burglary Verification Timer
Access to the programmable Cross Zone timer.
[005]>[000], option 3
Swinger Shutdown for Alarms
Access to the swinger shutdown limit for zone alarms
[377]>[001], option 1
For all non-fire zones, shut down at 1 to 6 trips.
Swinger Shutdown Enable
Access to swinger shutdown, transmission delay and cross zone attributes. Zone attribute option 6
(Swinger Shutdown enabled) is ON.
[002]>[001] - [128], option 6 ON
24-Hr. Auto-verified Fire
Access to 24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone type 025
Activates if Not restored within the specified time.
ON
Call Waiting Cancel
Access to the dialing sequence used to disable call waiting. Call waiting string can be programmed in
[304]
[382], option 4 OFF
System Test:
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
Refer to user manual (part no. 29008365).
[*][6] Master Code, option 04
Walk Test Mode:
This mode is used to test each zone on the system for proper functionality.
[*][8][Installer code][901]
Walk Test Communications
Enables communication of zone alarms while walk test is active.
[382], option 2
Walk Test Start/ End Reporting
Access to the reporting codes for walk test start and end times.
Codes
[308][401], options 1 and 2
PowerSeries Neo Installation Guide
- 27 -
Range/Default Requirement
Range:45- 255
Required
seconds
(programmable)
Default: 60 sec.
Default: Enabled
Required
If no exit after full
Required
arm
Default: Enabled
Default: Enabled
Allowed
Range: 30 sec. to 4
Required
min.
(programmable)
Default: 30 sec.
Default: Enabled
Required
Range: 00 - 45 sec.
Required
Default: 30 sees
(programmable)
Hard-coded ON
Required
Default: N
Required
Range: 005-255
Default: 005
A Cancel was
Required
transmitted
Default: Enabled
Programming
Required
required
Default: Disabled
Range: 000-255 sec.
Allowed
Default: 60 seconds
Default: 2 trips
Required
(programmable)
Non-police response
Allowed
zones
Default: Enabled
Must choose zone
Required
type for application
Depends on user
Required
phone line
Default: Disabled
Default: Disabled

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs2016Hs2128Hs2032Hs2064

Table of Contents