16. INSTALLATION OF DISPLAY AND RECEIVER PANEL

16.1 DESCRIPTION OF DISPLAY AND RECEIVER PANEL
1
1
MANUAL Button
* This button is used to operate the unit temporarily in case you misplace
the remote control or its batteries are exhausted.
* Once you push temporary button, the air conditioner will run in such order :
Auto, Forced cool, off and back to Auto
AUTO
The OPERATION lamp is lit, and the air conditioner will run under AUTO mode.
The remote controller operation is enabled to operate according to the received signal.
FORCED COOL
The OPERATION lamp flashes, the air conditioner will turn to AUTO after it is enforced to cool
with a wind speed of HIGH for 30 minutes. The remote controller operation is disabled.
OFF
The OPERATION lamp goes off. The air conditioner is OFF while the remote controller
operation is enabled.
OPERATION green led
2
* OPERATION green led lights on when the air conditioner operates
* OPERATION green led lights off when the air conditioner stops
TIMER green led
3
* TIMER green led lights on when timer function operates
* TIMER green led lights off when timer function stops
DEF. / FAN red led
4
* This led lights on when defrost protection is activated and lights off
when defrost protection terminates in heat mode.
ALARM red led
5
ALARM red led flashes when there is a malfunction in outdoor unit
Infrared Signal Receiver
6
( In case of using remote control )
Display Digital Tube
7
* This display shows error code in case of a malfunction.