Meaning Of The Leds On The Hla Module - Siemens SINAMICS S120 System Manual

Hydraulic drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Hardware

6.3 Meaning of the LEDs on the HLA module

6.3
Meaning of the LEDs on the HLA module
Table 6- 16
Meaning of the LEDs on the HLA module
LED
Color
RDY
-
Green
Orange
Red
Green/
red
Green/
red
Green/
orange
or
Red/
orange
P26.5 OK
-
Green
220
Status
Off
The electronics power supply is missing or outside the
permissible tolerance range.
Continuous
The component is ready for operation. Cyclic DRIVE-CLiQ
light
communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
This component has at least one fault.
light
Note
The LED is activated regardless of whether the corre-
sponding messages have been reconfigured.
Flashing
Firmware is being downloaded.
0.5 Hz
Flashing 2
Firmware download has been completed. The module
Hz
waits for POWER ON.
Flashing
Component recognition via LED is activated. This re-
light
sponse is parameterizable (see SINAMICS S120/150 List
Manual).
Note:
Both options depend on the LED status when component
recognition is activated.
Off
The 26.5 V supply is missing or outside the permissible
tolerance range.
Continuous
The 26.5 V supply is available.
light
The system does not monitor and display an overvoltage.
Description, cause
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Remedy
Acknowledge the fault.
Carry out a POWER
ON.
Connect the power
supply.
Check the voltage
tolerance at the HLA
module connector.
When doing this, take
into account the load-
dependent voltage
tolerance as a result of
the cable resistances.
Hydraulic Drive

Advertisement

Table of Contents
loading

Table of Contents