HP E2494A Installation Manual
HP E2494A Installation Manual

HP E2494A Installation Manual

Probe adapter for the intel pentium ii mobile processor

Advertisement

Quick Links

About this Manual
We've added this manual to the Agilent website in an effort to help you support
your product. This manual is the best copy we could find; it may be incomplete
or contain dated information. If we find a more recent copy in the future, we will
add it to the Agilent website.
Support for Your Product
Agilent no longer sells or supports this product. Our service centers may be able
to perform calibration if no repair parts are needed, but no other support from
Agilent is available. You will find any other available product information on the
Agilent Test & Measurement website, www.tm.agilent.com.
HP References in this Manual
This manual may contain references to HP or Hewlett-Packard. Please note that
Hewlett-Packard's former test and measurement, semiconductor products and
chemical analysis businesses are now part of Agilent Technologies. We have
made no changes to this manual copy. In other documentation, to reduce
potential confusion, the only change to product numbers and names has been in
the company name prefix: where a product number/name was HP XXXX the
current name/number is now Agilent XXXX. For example, model number
HP8648A is now model number Agilent 8648A.

Advertisement

Table of Contents
loading

Summary of Contents for HP E2494A

  • Page 1 Agilent Test & Measurement website, www.tm.agilent.com. HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy.
  • Page 2: Installation Guide

    Installation Guide Publication number E2494-92001 March 1998 © Copyright Hewlett-Packard Company 1997, 1998 All Rights Reserved HP E2494A Probe Adapter for ® the Intel Pentium II Mobile Processor...
  • Page 3: Installation At A Glance

    Installation at a Glance This Installation Guide shows how to connect Hewlett-Packard’s ® HP E2494A Probe Adapter to an Intel Mobile Pentium II processor. This probe adapter provides a quick and reliable means of connecting the HP E2487A Preprocessor Interface to supported target systems, using the 190-pin Mictor connector.
  • Page 4: Equipment Supplied

    Equipment Supplied • Probe adapter • This Installation Guide Minimum Equipment Required • For target systems using a Pentium II Mobile Module, a Pentium II Instrumented Mobile Module is required. • For target systems using a Pentium II Mobile Processor, an Instrumented Interposer board is required.
  • Page 5: To Connect The Probe Adapter To The Hp E2487A Preprocessor Interface

    To connect the probe adapter to the HP E2487A Preprocessor Interface To connect the probe adapter to the HP E2487A Preprocessor Interface The probe adapter has five high-density connectors, labeled Cable P1 through Cable P5. The HP E2487A Preprocessor Interface also has five high-density cables, labeled P1 through P5.
  • Page 6: To Connect To The Target System

    Instrumented Interposer board, using the 190-pin Mictor connector. The probe adapter connects to both types of target systems in a similar manner. You must have the appropriate board for connecting the HP E2494A to your target system. For target systems using a Pentium II Mobile Module, a Pentium II Instrumented Mobile Module is required.
  • Page 7 To connect to the target system Plug the probe adapter into the 190-pin Mictor connector on the Pentium II Instrumented Mobile Module, ensuring that Pin 1 is properly aligned (see illustration below). Damage to the connectors on the target system and probe adapter can result C A U T I O N from incorrect connection.
  • Page 8 To connect to the target system Attach the fully-connected probe adapter/Instrumented Mobile Module assembly to the connectors on the mother board. Connecting to the Pentium II Instrumented Mobile Module target system Adjust the screws until they are making contact with the mother board.
  • Page 9 Connecting to the Pentium II Mobile Processor mounted on Intel’s Instrumented Interposer board To protect your equipment, remove the power from both the HP E2487A C A U T I O N Preprocessor Interface and the target system before you make or break connections.
  • Page 10 To connect to the target system Plug the probe adapter into the 190-pin Mictor connector on the Instrumented Interposer board (see illustration below). Damage to the connectors on the target system and probe adapter can result C A U T I O N from incorrect connection.
  • Page 11 To connect to the target system Adjust the adjustment screws until they are making contact with the interposer board. Ensure that the probe adapter is firmly seated in the 190-pin Mictor connector, and that the probe adapter is parallel within ±4° with the interposer board (see illustration below). The adjustment screws must be properly adjusted so that they are touching C A U T I O N the interposer board, and the probe adapter is parallel within ±4°...
  • Page 12: To Disconnect The Preprocessor Interface From The Probe Adapter

    To protect your equipment, remove the power from both the HP E2487A C A U T I O N Preprocessor Interface and the target system before you make or break connections.
  • Page 13: Probe Dimensions

    Probe dimensions Probe dimensions The figure below gives the dimensions for the HP E2494A Probe Adapter. The dimensions are listed in inches and millimeters. Dimensions...
  • Page 14 © Copyright Hewlett- Safety Warning Safety Symbols • Packard Company 1997, 1998 This apparatus has been Service instructions are for All Rights Reserved. designed and tested in trained service personnel. To accordance with IEC avoid dangerous electric Instruction manual symbol: Publication 348, Safety shock, do not perform any Reproduction, adaptation, or...
  • Page 15 This Hewlett-Packard system This is the first edition of the product is warranted against No other warranty is HP E2494A Probe Adapter defects in material and expressed or implied. for the Intel Pentium II workmanship for a period of...

Table of Contents