Step 21: Turn the generator to the non-pull cord side of
and screw in the top two Phillips screws. Next, install the
spark plug access cover that was removed in step 3.
Step 22: Turn the generator to the control panel side and
reinstall the control panel assembly by tipping the top
forward so that the tabs line up. Screw in the 4 Phillips
screws removed in step 4. The two longest screws go on
top of panel. Reinstall the OFF-RUN-CHOKE switch in
the upper right hand part of the control panel and secure
with Phillips screw. IMPORTANT: Make sure the switch is
installed in the correct orientation with the off state being
vertical.
Step 23: Replace the 3 10mm bolts at the bottom of the
pull cord side of the generator.
Step 24: Make sure to take the generator outside to a
well ventilated area and run it to confirm there are no
issues with installation. Switch the economy mode on and
off and check for major RPM changes.