Step 6: On the bottom of the pull cord side of the
generator remove the 3 10mm bolts that hold the side
cover on.
Step 7: Detach the pull cord side cover. Start by pulling
the muffler side of the cover and work towards the gas
cap side. There is a groove under the gas cap that can
be detached by pulling upward and outward. Once the
panel is removed let it lean outward so you can access
the engine. The recoil does not need to be removed to
perform ignition coil replacement.
Step 8: In the center of the unit lift up on the gas tank to
access the ignition coil assembly. Remove the 8mm bolt
that holds the ignition coil to the engine.
Step 9: Pull the spark plug boot off of the spark plug on
top of the engine.
Step 10: Unplug the three wire connections to the ignition
coil assembly. Once the ignition coil is detached, discard it.