Download Print this page

Coils / Thermistors - Daikin RKM71PVMG Service Manual

Removal procedure 6.0/6.3/7.1 kw class 24000/28000 btu/h class

Advertisement

Coils / Thermistors

5. Coils / Thermistors
Warning
Step
1
Pull out the electronic
expansion valve coil.
2
Remove the screw and
remove the four way
valve coil.
3
Pull out the outdoor
heat exchanger
thermistor.
12
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Electronic
expansion
valve coil
Four way
valve coil
Outdoor heat exchanger thermistor
(R11159)
The cooling only models
have no four way valve coil.
(R18110)
Be careful not to lose the clip
for the thermistor.
(R11160)
Si001271EE
Points
Clip
(R3264)
Removal Procedure