4. Fan Motor

Warning
Step
1
Remove the 2 lower
screws first.
2
Then, remove the 2
upper screws.
3
Remove the fan motor.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
2
1
Fan motor
Be sure to remove the lower
screws first. If the top screws
are removed first, the fan
motor may tilt down or fall
and cause injury because its
center of gravity is shifted to
the front.
(R6442)
When reassembling, make
sure that the wire harness is
facing downward.
Harness
(R6443)
Fan Motor
Points
(R6444)
11