Si001271EE
3. PCBs
Warning
Step
1
Remove the cover of
the electrical box.
2
Disconnect the
connectors [S52]
[S102] from the service
monitor PCB.
3
Detach the 4 clamps
with pliers and remove
the service monitor
PCB.
4
Remove the screws of
the terminal board and
the earth / ground wire.
5
Unfasten the hook on
the right.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Hook
[S52] [S102]
Service monitor PCB
Clamp
Terminal board
Hook
Cover
(R18913)
(R16707)
(R16708)
Hook
Earth / ground wire
(R18968)
Points
Release the 4 hooks. The
hooks are indicated by
(R6427)
[S52], [S102]: to main PCB
PCBs
.
9