Connect To Ground - TP-Link TL-R480T+ Installation Manual

Load balance broadband router
Hide thumbs Also See for TL-R480T+:
Table of Contents

Advertisement

Load Balance Broadband Router
>5kVA
powerline
Device
Switch case
Transformer room
Elevator tower
Air-conditioner room
3.2

Connect to Ground

Connecting the device to ground is to quickly release the lightning over-voltage and
over-current of the device, which is also a necessary measure to protect the body from
electric shock.
In different environments, the device may be grounded differently. The following
will instruct you to connect the device to the ground in two ways, connecting to the
grounding bar or connecting to the ground via the power cord. Please connect the
device to ground in the optimum way according to your specific operation environment.
Connecting to the Ground via the Power Supply
If the device is installed in the normal environment, the device can be grounded via the
PE (Protecting Earth) cable of the AC power supply as shown in the following figure.
Figure 3-1
Lightning Protection
10
Parallel cabling
One is in the grounded metal raceway or metal pipe
The both are in the grounded metal raceway or metal pipe
Min Distance (m)
1.00
2.00
2.00
2.00
Connecting to the Ground
Note:
The figure is to illustrate the application and principle. The power plug you get
from the package and the socket in your situation will comply with the regulation
in your country, so they may differ from the figure above.
If you intend to connect the device to the ground via the PE (Protecting Earth)
cable of AC power cord, please make sure the PE (Protecting Earth) cable in the
electrical outlet is well grounded in advance.
600
300
150

Advertisement

Table of Contents
loading

Table of Contents