Commissioning, inspection, maintenance
Further details regarding the individual steps

Filling the siphon with water

B
A
C
50
(cont.)
1. Pivot control unit forward.
2. Remove retaining clip A.
3. Pull filler pipe B upwards.
4. Remove trap C downwards.
5. Fill siphon with water and refit.
6. Check that the condensate pipe is
connected correctly to the siphon and
heat exchanger.
Note
Route the drain hose without any
bends and with a constant fall.
7. Refit cover panel.
8. Secure control unit back into the
operating position.