Dvd Laser Current Measurement; Cd Laser Current Measurement - Denon DCD-1500AE Service Manual

Super audio cd player
Hide thumbs Also See for DCD-1500AE:
Table of Contents

Advertisement

4.1. DVD Laser current measurement

LD(DVD)
+5V-M2
(1) Connect the oscilloscope to +5V-M2 of test point for GND
side and LD(DVD) of test point for signal side.
(2) Playback the stereolayer track 1 of the SACD Test Disc.
(3) Measure the voltage between +5V-M2 and LD(DVD), cal-
culate Iop by the formula as shown below.
Measurement Voltage Value
Iop
=
---------------------------------------------------------------------------- -
14 (Resistance value)

4.2. CD Laser current measurement

(1) Connect the oscilloscope to +5V-M2 of test point for
GND side and LD(CD) of test point for signal side.
(2) Playback the track 1 of the CD Test Disc.
(3) Measure the voltage between +5V-M2 and LD(CD), cal-
culate Iop by the formula as shown below.
Measurement Voltage Value
Iop
=
---------------------------------------------------------------------------- -
11.75 (Resistance value)
Oscilloscope
1U-3624 SACD MODULE P.W.B. unit foil side
9
4.1. DVD レーザー電流測定
LD(DVD)
+5V-M2
(1) オシロスコープをテストポイント
LD(DVD)( 信号 ) へ接続します。
(2) SACD テストディスクのステレオレイヤートラック 1 を
再生します。
(3) +5V-M2 と LD(DVD) 間の電圧を測定し、次式により Iop を
算出します。
測定電圧値
Iop
=
---------------------------- -
14(抵抗値)
4.2. CD レーザー電流測定
(1) オシロスコープをテストポイント
LD(CD)( 信号 ) へ接続します。
(2) CD テストディスクのトラック 1 を再生します。
(3) +5V-M2 と LD(CD) 間の電圧を測定し、 次式より Iop を算
出します。
測定電圧値
Iop
=
----------------------------------- -
11.75(抵抗値)
DCD-1500AE
Oscilloscope
+5V-M2(GND)
+5V-M2(GND) と
LD (CD)
LD (DVD)
+5V-M2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents