1-13 Disassembly of Left Cover Unit 4

(1) Peel off the Caution Seal, remove five screws (i × 1, l × 2, r × 1, C × 1), and separate the Left Cover and Cassette Arm Unit.
< Note on Reassembling >
(1) Fold the FPC as shown in the figure when connecting it.
< Instruction for Supply >
Arm guide assembly in Cassette Arm Unit : FLOIL C-1Z
Left Cover
(1) - r
Note on Reassembling (1)
(1)
(1) - C
(1) - i
(1)
Caution Seal
Grease applying
Position
Floil C-1Z
Fig. 4-12