Standard Drive Control - Siemens SINAMICS G120 Compact Operating Instructions

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

4.2.2

Standard Drive Control

6.
7.
8. Enter the motor data:
CU240B-2 and CU240E-2 Control Units
Compact Operating Instructions, 04/2015, A5E35792002B AA
Motor standard
KW 50HZ
HP 60HZ
KW 60HZ
Supply voltage for the inverter
8.1.
8.2.
8.3.
8.4.
8.5.
8.6.
8.7.
8.8.
8.9.
4.2 Commissioning with BOP-2 operator panel
IEC
NEMA
IEC 60 Hz
Motor type
Depending on the particular inverter, it is possible that the BOP-2
does not list all of the following motor types.
INDUCT
Third-party induction motor
SYNC
Third-party synchronous motor
RELUCT
Third-party reluctance motor
1L... IND
1LE1, 1LG6, 1LA7, 1LA9 induction motors
1LE1 IND 100 1LE1☐9 with motor code on the rating plate
1PH8 IND
Induction motor
1FP1
Reluctance motor
1F... SYN
1FG1, 1FK7 synchronous motor, without encoder
If you have selected a motor type > 100, then you must enter the
motor code:
With the correct motor code, the inverter assigns the motor data
the following values.
If you do not know the motor code, then you must set the motor
code = 0, and enter the motor data from p0304 and onwards from
the rating plate.
87 Hz motor operation
The BOP-2 only displays this step if you previously selected IEC
as the motor standard (EUR/USA, P100 = KW 50HZ).
Rated voltage
Rated current
Rated power
Rated frequency
Rated speed
Motor cooling
SELF
Natural cooling
FORCED
Forced-air cooling
LIQUID
Liquid cooling
NO FAN
Without fan
Commissioning
21