System settings tool

13.3 Activation of system settings in system mode

Normal
If HMWIN runtime is not running:
operation
Touch the "System Setting" button on the HMI panel to open the system settings in
user mode. Select "Restart" > "Config OS" to reboot in system mode.
If HMWIN runtime is running:
To activate the system settings in user mode, touch and hold any unused area
of the touch screen for a few seconds to access the context menu. The default
holding time is 2 seconds. Select "Restart" > "Config OS" to reboot in system
mode.
Recovery
If the HMI panel is not responsive, tap on the surface of the touch screen during
operation
the power-up phase of the panel. The tapping frequency must be high. Start tap-
ping the touch screen as soon as power has been supplied to the panel.
The message "TAP-TAP DETECTED" appears when the operating sequence has
been recognized. Release the touch screen to boot in user mode without running
HMWIN runtime or touch and hold the touch screen for a few seconds. Then select
"Restart" > "Config OS" to boot in system mode.

13.4 Options available in system settings

The following important basic setting options of the panel are available:
Language
System
Logs
Date & Time
Network
Services
Management
Display
Restart
Authentication
NOTE
The system settings tool includes also other options that are not described and not documented in this
manual. For details, please refer to the HMWIN User Manual.
Configure the language used for the system setting menu only.
Shows information about platform, status and timers (e.g. system
on time, backlight on time).
Enable persistent log for BSP and allows to export it.
Change the date and time of the panel, including time zone and
NTP server.
Configure the IP address of the Ethernet interface and the other
network settings, e.g. DNS, gateway, DHCP, hostname.
Enable/disable services, e.g. OpenSSH server, cloud services,
SNMP and logging.
Update BSP components (Main OS, Config OS, Boot loader,
XLoader), check partition consistency, update the splash screen,
show the usage and size of partitions.
The update of "Main OS" is only available in system mode. The
update of "Config OS" is only available in user mode.
Adjust the brightness, configure automatic backlight turnoff and
select HMI orientation (90°, 180°, 270° and 360°).
Restart the panel.
Select "Main OS" to restart the panel in user mode (default set-
ting). Select "Config OS" to restart the panel in system mode and
open the system settings.
Configure the administrator ("admin") and the standard user
("user") password. An administrator has full access to the "System
Settings" (e.g. BSP updates and other system components). A
standard user has some limitations.
23