Real Time Clock; Event Log Reading - Siemens ATC5300 Manual

Automatic transfer controller
Hide thumbs Also See for ATC5300:
Table of Contents

Advertisement

3701h
3702h
3703h
3704h
3705h
3706h
3707h
3708h
3709h
370Ah
370Bh
370Ch
¿ The association between the numerical value and the function has to be done in a sequential
way, considering the function listed on the operative manual. The first function is obtained by
setting 0, while the last function by setting the maximum value allowed by the range.
À To select OFF, set the minimum numerical value allowed by range.
Á To select OFF, set the maximum numerical value allowed by range.
 The association between the numerical value and the function has to be done in a sequential
way, considering the function listed on the operative manual. The first function is obtained by
setting the maximum value allowed by the range, while the last function by setting value 0.
2.6

Real Time Clock

(To be used with functions 04 and 06)
To make the changes effective, store them using the dedicated command described in table 3.
ADDRESS WORDS
2F20h
2F21h
2F22h
2F23h
2F24h
2F25h
2F26h
2.7

Event Log Reading

The events history is stored in a circular buffer memory. To rebuild the correct time sequence,
it is necessary to read the position of the most recent event, indicated by the buffer pointer, and
go backward starting from it for a number of positions equal to the one indicated by the event
counter.
If the head of the circular buffer is reached (pos. 1), then it is necessary to move to the last
position (pos. 100, tail) and then go back until the most recent event is reached again. Time
stamp values are returned in compacted format, in three registers containing each a couple of
data. For instance register 2100h holds in the MSB the hours and in LSB minutes. The same
criteria is applied to seconds / day and month / year.
ATC5300
Modbus Communication Protocol, Edition 03/2011, A5E02469001-02
1
P8.02 Interval time (days)
1
P8.03 Enable test on Monday
1
P8.04 Enable test on Tuesday
1
P8.05 Enable test on Wednesday
1
P8.06 Enable test on Thursday
1
P8.07 Enable test on Friday
1
P8.08 Enable test on Saturday
1
P8.09 Enable test on Sunday
1
P8.10 Auto test begin hour
1
P8.11 Auto test begin minutes
1
P8.12 Duration time
1
P8.13 On load switching
PARAMETER
1
Seconds
1
Minutes
1
Hours
1
Weekday
1
Day
1
Month
1
Year (2000 → )
Data Library
2.6 Real Time Clock
1 ... 60
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 1 ¿
Unsigned integer
0 ... 23
Unsigned integer
0 ... 59
Unsigned integer
0 ... 600
Unsigned integer
0 ... 1 ¿
Unsigned integer
RANGE
FORMAT
0 ..59
Unsigned integer
0 ..59
Unsigned integer
0 ..23
Unsigned integer
1 ..7
Unsigned integer
0 ..31
Unsigned integer
1 ..12
Unsigned integer
0 ..99
Unsigned integer
25