Alcatel-Lucent 9768 User Manual page 45

Metro radio outdoor b4
Table of Contents

Advertisement

Installing an 9768 MRO B4
....................................................................................................................................................................................................................................
Powering up the device
Perform the following steps:
...................................................................................................................................................................................................
Test the power at the power source.
1
...................................................................................................................................................................................................
If power to the receptacle outlet has been shut off, turn it on.
2
...................................................................................................................................................................................................
3
Near immediately after the model is powered, it can begin to transmit RF signals and thus
becomes a potential hazard of human irradiation from that RF. Nonionizing radiation of
this kind may damage human tissue or cause other health problems, even at doses far
below those that produce perceptible heating.
For more information on the safe separation distance, see
(p.
1-4).
Plug the power cord into the power source.
...................................................................................................................................................................................................
4
Begin observing and noting the changes that occur in the LED indications of the 9768
MRO.
On the bottom of the Alcatel-Lucent 9768 MRO, a single visible LED provides local
diagnostic indications. The LED indications have specific meanings, as defined in the
following table:
Table 3-1
If the LED is...
not lit at all
steady-lit green
blinking green
steady-lit yellow
blinking yellow
....................................................................................................................................................................................................................................
3-22
CAUTION
RF hazard
LED interpretations
then the indication is that...
the 9768 MRO is not powered.
the 9768 MRO is powered, its RF functions are enabled, and its links with the
9926 d2U Base Band Unit are active.
the 9768 MRO is not transmitting.
the slave link between this 9768 MRO and the next 9768 MRO in a
daisy-chained configuration has a fault. Where a daisy chain is not
implemented (as in the initial release of this product, which does not support
daisy chaining), this LED condition will not be seen.
a download of firmware is occurring.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 3-1: Installing the 9768 MRO B4 onto a wall or
"Safe separation distance"
pole
Alcatel-Lucent 9768 MRO
3MN-MRO-AWS-IMOP
Issue 1 February 2014