Installing an 9768 MRO B4
....................................................................................................................................................................................................................................
Installing RF antenna cables for 9768 MRO B4
Perform the following steps:
...................................................................................................................................................................................................
Connect TxRx1 and TxRx2 antenna cables to the 9768 MRO B4. The 9768 MRO B4 uses
1
a 4.1/9.5 miniDIN RF connectors.
Figure 3-10 RF connectors
...................................................................................................................................................................................................
2
Torque the miniDIN connectors to 10 Nm (7.5 ft lb).
...................................................................................................................................................................................................
Locate the surge protector within reach of the RF jumper cable from 9768 MRO B4.
3
Note: See instructions that comes with the surge protection kit for more information.
...................................................................................................................................................................................................
Mount the surge protector to a wall or panel using the bulkhead nut provided with the
4
protector.
...................................................................................................................................................................................................
Attach the 6 AWG ground cable (wire provided with the surge protector kit) to the
5
protector body using the M8 hardware.
...................................................................................................................................................................................................
6
Attach the other end of the ground wire to the site grounding system.
....................................................................................................................................................................................................................................