2. INSTALLATION OF THE OVEN

The oven must be set up on a perfectly flat surface and left standing
free. Make sure to allow enough room at the back for easy access to the
terminal strip for connection of the power cable to mains.
Installation must be carried out by a qualified technician in compliance
with applicable regulations in force.
2.1 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located to the rear of the oven. This rating
plate must never be removed.
The connection terminals are
located at the rear of the
appliance.
connections
diagram. For access to the
terminal board, remove the
door located at the back of
the oven.
For operation on 380-415V3N
H07RN-F-type five-core cable (5 x 1.5 mm
For operation on 220-240V
H07RN-F-type three-core cable (3 x 4 mm
The cable end to be connected to the
appliance must be provided with an ground
wire (yellow-green) at least 20 mm longer.