When RFID modules are used, different components in the overall system can act as a
coupling path:
Table 4- 2
Coupling path
Conductors and cables
Control cabinet or housing
4.7.5

Prevention of interference sources

A high level of immunity to interference can be achieved by avoiding interference sources.
All switched inductances are frequent sources of interference in plants.
SIMATIC RF600
System Manual, 05/2012, J31069-D0171-U001-A13-7618
Ways in which interference can be coupled in
Causes of coupling paths
4.7 Guidelines for electromagnetic compatibility (EMC)
Invoked by
Incorrect or inappropriate installation
Missing or incorrectly connected shield
Inappropriate physical arrangement of cables
Missing or incorrectly wired equalizing conductor
Missing or incorrect earthing
Inappropriate physical arrangement
Components not mounted securely
Unfavorable cabinet configuration
RF600 system planning
87