Check list

You can use the following list to check whether the basic connections for the RIVAGE PM7 system are working properly.
Both power A and B for each device must be turned on.
Make sure that two power cords are connected to each device and that both power switches A and B on
each device are turned on.
Fiber optic cables for the TWINLANe network and CAT5e cables for the console network must be connected
between IN and OUT jacks respectively to form a ring topology.
Connecting IN jacks to IN jacks or OUT jacks to OUT jacks does not work. Make sure you connect the cables properly.
44
RIVAGE PM7 System Setup Guide
An HY card (HY256-TL) must be installed in HY card slot 1 on the
rear panel and the I/O rack.
An HY card does not work in card slots 2 and 3 on the rear panel.
Install the card in card slot 1 on the rear panel or on the I/O rack.
The I/O rack must be connected to and recognized by the system
(SYSTEM CONFIG screen).
Press the I/O rack select button to set the rack correctly
(
page 38).
Channels must be assigned to the TWINLANe network correctly
(SYSTEM CONFIG screen).
Modify channel assignment so that the total number of channels
used on the TWINLANe network is 400 or less across all components.
Refer to "Assigning channels to the TWINLANe network
(
page 38)" to make sure that your I/O rack settings are correct.
Refer to "Assigning channels to the TWINLANe network
(
page 38)" to make sure that your DSP settings are correct.
The input ports must be patched correctly (Input Patch screen).
Refer to "Patching input ports (
how to patch input ports correctly.
The output patches must be set correctly (on the DSP engine setting
screen).
Refer to "Patching output ports (
on how to patch output ports correctly.
The word clock must be set correctly (WORD CLOCK screen).
Refer to "Setting the word clock (
on how to set the word clock correctly.
The status of TWINLANe network communication must be normal.
(The indicators of the HY256-TL.)
Make sure that the fiber optic cables are properly connected.
The synchronization must be finished (DEVICE SYNC screen).
Press the SYNC button to set the synchronization correctly
(