3.3

Quarterly Inspections

3.3.1

Check Items

Check the items listed in the table below every three months.
No.
Check:
Robot base
mounting bolts
1
Cooling fan
filters in the
2
robot controller
3.3.2

Cleaning the Air Intake Filter in the Robot Controller

For the cleaning procedures of the air intake filter, refer to the RC7M CONTROLLER
MANUAL, Section 6.4 "Cleaning the Air Intake Filter."
Quarterly Inspections Table
Controller
How to check:
Power
OFF
Measure the tightening
torque with a torque
wrench.
OFF
Visually
Criterion
No looseness.
Specified torque:
35 7 Nm
No dust or dirt.
29
What to do:
Tighten the bolts to the
specified torque.
Clean the cooling fan
filters. (Refer to
Section 3.3.2.)