Option 37 - Set time duration of override rule
(Option 36 set to 1 or 2)
This establishes the duration of a temperature
override available to the user. Press + until Option 37
is displayed, use V and Λ to select required setting.
GB
Setting 0
Setting 1
Setting 2
GR
Setting 3
Setting 4
TR
Option 38 - Relay state on low battery detect
LV
(battery products only)
This establishes the position that the relay is driven to
when the unit shuts down due to low battery state.
LT
Press + until Option 38 is displayed, use V and Λ to
select required setting.
UA
Setting 0
Setting 1
RU
Option 40 - Number of Events per Day
This sets the thermostat to operate with either 2, 4 or
6 switching events per day or to run it in stat mode.
Press + until option 40 is displayed, use Λ or V to select
required setting.
1
2
4
6
Option 41 - Operating Mode (5/2 day or 24 hour)
This sets the thermostat to operate using either
5/2 day or 24 hour mode. Press + until option 41 is
displayed, use Λ or V to select required setting.
5-2
24
12
Next event (factory setting)
1 hour
2 hours
3 hours
4 hours
Relay parked with output OFF (factory setting)
Relay parked with output ON
Stat mode
Two switching events per day
Four switching events per day
Six switching events per day (Factory setting)
5/2 day (Factory setting)
24 hour
TP5001