Heat Pump
MUST BE COMPLETED AND
THEN REGISTERED ONLINE

Installation Checklist

TO COMPLETE WARRANTY
Please register your product online
Heating Controls
Is the unit installed the correct distance from nearest boundaries?
Is the unit secured correctly to antivibration mounts via rubber mounts?
Is the unit mounted plumb level?
Is condensate drain kit fitted? (drain kit located inside HP access door)
If unit is mounted on wall brackets, is drip tray installed?
Heat Pump Plumbing (Outdoor)
Is correct size pipe work used?
Are flexible antivibration hoses fitted and washers used?
Are heat pump isolation valves fitted out at the heatpump?
Is Y-Strainer fitted on the return pipework to heat pump and fitted in the correct orientation?
Is flow and return pipe work connected the right way around?
Is Primary flow and return pipework insulated?
Cylinder Plumbing (Indoor)
Is the flow switch installed on the primary pipework and fitted in the correct orientation? (Smart
Plumb Compact not applicable)
Is the flow switch installed on the primary horizontal pipework with 150mm pipe work each side
free of a bend or appliance? (Smart Plumb Compact not applicable)
Is Flow and Return pipe work connected the right way around?
Is the heating expansion vessel correctly sized, secured and charged to correct pressure? (Smart
Plumb Compact not applicable)
Is the Potable expansion vessel secured and charged to the correct pressure?
Are all pump valves and isolating valves fully open?
Has system been completely flushed of air and charged to the correct operating pressure of 2 bar?
Are all safety valves and tundish drained through a metal pipe to an appropriate drain point?