Download Print this page

Coils / Thermistors - Daikin RKM33NV2S Service Manual

Removal procedure
Hide thumbs Also See for RKM33NV2S:

Advertisement

Si001272EC

5. Coils / Thermistors

Warning
Step
1. Remove the electronic
expansion valve coil.
1
Pull out the electronic
expansion valve coil.
2. Remove the thermistors.
1
Pull out the outdoor
heat exchanger
thermistor.
Slightly open the sound
2
blanket (outer).
3
Remove the sound
blanket (top upper).
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Outdoor heat exchanger thermistor
Sound blanket
(top upper)
Electronic
expansion
valve coil
(R9631)
(R17236)
Sound blanket
(outer)
(R18075)
Coils / Thermistors
Points
The position of the outdoor
heat exchanger thermistor
varies depending on the
model.
Be careful not to lose the clip
for the thermistor.
Clip
(R22516)
You can remove the
thermistors without removing
the electrical box.
(1) Disconnect [S90] from the
electrical box (main PCB).
(2) Release the thermistor
harness from the hook at the
bottom of electrical box.
(3) Pull out the clamp of the
thermistor harness from the
hole of the electrical box.
The design of the sound
blankets varies depending
on the model.
13

Hide quick links:

Advertisement

loading