INSTALLATION Continued

Electrical Connections

Before attempting the electrical connection, the rating
plate should be checked to ensure that the unit's electrical
characteristics and the supply electrical characteristics agree.
THE ELECTRICAL POWER LINES MUST BE INSTALLED IN
ACCORDANCE WITH:
- The National Electrical Code, ANSI/NFPA No. 70 latest
edition (USA)
- Canadian Electrical Code, CSA C22.2
- Any other applicable National, State or municipal codes and
regulations..
THE FOLLOWING CONDITIONS MUST BE ADDRESSED:
1. Switch panel size
2. Overload protection
3. Wire type
4. Wire size
5. Temperature limitations of the wires
6. Method of connection (Cable, Conduit, etc.)
The service line will enter through the rear of the unit and is
Part Number 260BGL rev C 4/15
to be connected to the terminal block (see diagram below).
The terminal block is accessed by removing the right side
body panel.
Input voltage and phasing must match the units voltage
and phasing. Wiring diagram is attached to the main back of
each oven. Visually check all electrical connections. Energize
electric service to units. The range is wired standard for three
phase connections. If it is necessary to change to single
phase, please refer to wiring diagram attached to the rear of
the oven. Service and unit voltage must agree.