WARNING!
Risk of falling
The user can fall over the edge and get seriously
injured, if the vertical distance A between the
top of the mattress and the edge of the side
rail/bed end, is too short. See image above.
– Always keep a minimum distance A of 22 cm.
– Follow the maximum mattress height in
combination with the side rail as stated in the
mattress table in chapter 7 Technical Data,
page 17.
2.3 Safety information on
electromagnetic interference
WARNING!
Risk of malfunction due to electromagnetic
interference
Electromagnetic interference between this
product and other electrical equipment can occur
and disturb the electrical adjustment functions
of this product. To prevent, reduce or eliminate
such electromagnetic interference:
– Only use original cables, accessories and spare
parts, to not increase electromagnetic emission
or reduce electromagnetic immunity of this
product.
– Do not use portable radio frequency (RF)
communications equipment closer than 30 cm
to any part of this product (including cables).
– Do not use this product near active
high-frequency surgical equipment and the
RF shielded room of a system for magnetic
resonance imaging, where the intensity of
electromagnetic disturbances is high.
– If disturbances occur, increase the distance
between this product and the other equipment
or switch it off.
– Refer to the detailed information and follow
the guidance in chapter 8 Electromagnetic
compatibility (EMC), page 20.
1567446-H
A
WARNING!
Risk of malfunction due to electromagnetic
interference
Do not use this bed adjacent to or stacked with
other electrical equipment, than specified in the
following, as it could result in improper operation.
If such use is necessary, the bed and the other
equipment must be closely observed to verify
that they are operating normally.
This bed can be used together with Invacare
approved accessories and medical electrical
equipment connected to the heart (intracardially)
or blood vessels (intravascularly) provided that
following points are respected:
– Medical electrical equipment should not be
fixed on the bed's metallic accessories such as
side rails, lifting pole, drip rod, bed ends, etc.
– The medical electrical equipment power supply
cord should be kept clear of the accessories or
any other moving parts of the bed.

2.4 Labels and symbols on the product

2.4.1 Product label

Invacare Rea AB
Växjövägen 303
34375 Diö - Sweden
XXXXXX XXXXX_XX
XXXXXXXXXXXXX
The product label is placed on the frame of the bed and
contains the main product information, including technical
data.
Symbols
Serial Number
Reference Number
Manufacturer Address
Manufacturing Date
Max. User Weight
Max. Safe Working Load
CLASS II equipment
Type B Applied Part
WEEE conform
This product complies with Directive 93/42/EEC
concerning medical devices. The launch date
of this product is stated in the CE declaration
of conformity.
Safety
EN 60601-2-52
YYYY
- MM
HMI: 79007