Spray - Graco ToughTek M680a Operation - Repair - Parts

Cs mortar sprayer
Hide thumbs Also See for ToughTek M680a:
Table of Contents

Advertisement

12. To stop dispensing, close the air motor pilot ball
valve (G).
F
. 26: Close Pilot Ball Valve (on Applicator)
IG
13. Place the applicator outlet into the hopper.
14. Open the air motor pilot ball valve (G). Material will
begin dispensing.
15. Recirculate a few gallons of material to be sure the
material is flowing properly.
16. Install a tip onto applicator. The system is now
primed and ready to spray.
3A5275B

Spray

Prevent Packout
G
To avoid material packout or interruption of material
M
flow:
Use the lowest pressure and largest nozzle size that
U
provides an acceptable spray pattern. This will also
result in seals and wear parts lasting much longer.
Do not use any more fluid hose than is necessary.
Use an applicator with a rubber tip retainer that will
blow off if it plugs.
Before Starting or Stopping Material Flow
Start and stop the fluid flow with the red-handled air
ti21579a
motor pilot valve at the applicator.
Always have the atomizing air turned on before and
after spraying fluid.
Before Starting Material Flow
1. Always open the air assist shutoff ball valve (U) and
adjust needle valve for air assist flow control (M)
first.
2. Open (turn on) the air motor pilot ball valve (G) last.
Before Stopping Material Flow
1. Always close (turn off) the air motor pilot ball valve
(G) first.
2. Turn off the air assist shutoff ball valve (U).
Spraying
Do not allow pump to run without material in the hop-
per. It will quickly accelerate to a high speed, causing
pump seal damage.
To prevent material curing in the system, never load
mortar into a dry system. Loading mortar into a dry
system will cause the mortar to stick to internal com-
ponents and cure, causing damage and requiring
replacement of those parts.
Operation
NOTICE
NOTICE
17