Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, splashing fluid, and moving parts,
follow the Pressure Relief Procedure when you stop
spraying and before cleaning, checking, or servicing
the equipment. Never open a camlock hose or
applicator fitting while there is pressure in the fluid
line.
1. Close the bleed type master valve (B).
F
. 13
IG
12
2. Set air pressure regulator knob (F) to zero pressure.
3. Hold applicator firmly against a grounded metal pail.
F
IG
4. If you suspect the applicator tip or hose is
Material can harden inside of the pressure relief ball
valve (J) if it is not flushed properly after use. If there
is hardened material within the pressure relief ball
valve, pressure may not be effectively relieved. See
Flush the Equipment, page 19.
B
A
ti21575a
. 14
completely clogged, or that pressure has not been
fully relieved after following the previous steps,
slowly open the pressure relief ball valve (J) at the
pump outlet. See Component Identification, page
8.
NOTICE
ti21632a