Test Installed Fitting; Install Pop-Up Drain - American Standard Townsquare 2555.801 Installation Instructions

Spread lavatory faucets with everclean finish

Advertisement

TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2)
and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES to flush water lines thoroughly.
Replace AERATOR (3).

INSTALL POP-UP DRAIN

Push Tail piece (11) down into Trap (C) (threaded end up).
Thread Locknut (5), Washer (4) and Gasket (3) (Bevel side
up) onto Drain Body (10).
Apply a bead of Putty (D) to underside of Flange (2).
Feed Drain Body (10) up through Sink (A) and thread the
Flange (2) fully onto Drain Body (10).
Tighten Locknut (5) firmly, keeping the pivot rod hole pointed
towards the back of the sink.
Assemble Pivot Rod (9) as shown in Figure-4B. Notice the
position of the Concave Washer (G).
Insert Pivot Rod (9) into Drain Body (10) and tighten Pivot
Nut (F).
Push TAILPIECE INSERT (12) into TAILPIECE (11) and push
TAILPIECE up and thread tightly into DRAIN BODY (10).
Position Extension Rod (7) onto Pop-Up Rod (E) and tighten
Thumbscrew (6).
Remove one end of Clip (8) from Pivot Rod (9) by squeezing
ends together while sliding.
Insert Pivot Rod (9) into second or third hole in Extension
Rod (7) and reassemble Clip (8).
Drop Stopper (1) into Drain Body (10).
Adjust stopper height by repositioning Extension Rod (7) and
tightening Thumbscrew (6).