Test Installed Fitting; Check Drain Connections; Service; Care Instructions - American Standard Triumph 7034 Installation Instructions Manual

Centerset lavatory faucet with speed connect drain
Table of Contents

Advertisement

9

TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
10

SERVICE

To change direction of handle:
Turn valve to OFF position
Pull HANDLE ASSEMBLY (1) "UP" firmly to release
from ADAPTER (2).
Remove ADAPTER SCREW (3) from ADAPTOR (2).
Pull off ADAPTER (2).
Remove SPRING CLIP (4). Lift STOP WASHER (5),
turn 90˚ and replace. Replace SPRING CLIP (4).
Replace ADAPTER (2) and ADAPTER SCREW (3).
Find correct position of HANDLE ASSEMBLY (1)
by adjusting male teeth on ADAPTER (2) to female
teeth in HANDLE ASSEMBLY (1).
Push HANDLE ASSEMBLY (1) down onto
ADAPTER (4) until it snaps into place.
11

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
4
1
Tighten
90˚
4
4
5
WASTE
OUTLET
2
1
3
5
2
1
3
2
"P" TRAP
M 9 6 8 8 6 5 R e v . 1 . 2

Advertisement

Table of Contents
loading