Hydraulic linear drive
Table of Contents

Advertisement

Note: For complete connection and installation instructions for
the course computer refer to the documentation that accompanies
the unit.
Cable extensions
You may need to extend the Hydraulic Linear Drive cables.
• Clutch cable (from hydraulic ram to course computer clutch
connection) — use minimum 1.5 mm
• Motor cable (from Hydraulic pump to course computer motor
connection) — use the following table to determine the correct
cable gauge required:
Drive type
Cable length
Type 2 (12 V)
Up to 5 m (16 ft)
Up to 7 m (23 ft)
Up to 16 m (52 ft)
Type 2 (24 V)
Up to 3 m (10 ft)
Up to 5 m (16 ft)
Up to 10 m (32 ft)
Up to 16 m (52 ft)
Up to 5 m (16 ft)
Type 3 (12 V)
Up to 7 m (23 ft)
Up to 16 m (52 ft)
Type 3 (24 V)
Up to 5 m (16 ft)
Up to 7 m (23 ft)
Up to 16 m (52 ft)
Cables and connections
2
(16 AWG) copper cable.
Cable gauge
Cable gauge
(AWG)
(mm
2
)
10
6
8
10
6
16
12
4
10
6
8
10
6
16
8
10
6
16
4
25
10
6
8
10
6
16
Use suitable electrical connectors or junction boxes to connect the