Door Replacement And Adjustment - Electrolux ICON E30SO75ESS Technical & Service Manual

High speed convection microwave oven
Hide thumbs Also See for ICON E30SO75ESS:
Table of Contents

Advertisement

6. Secure the screws firmly.
7. Check all of the switches operation. If any switch has
not activated with the door closed, loosen the screws
and adjust the position of the latch hook right and the
latch hook left.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm
when in the latched position. First check position of
latch hook right, pushing and pulling right portion of
door toward the oven face. Then check position of
the latch hook left, pushing and pulling left portion of
the door toward the oven face. Both results (play in
the door) should be less than 0.5mm.
2. The door sensing switch, and secondary interlock
switch interrupt the circuit before the door can be
opened.
3. The monitor switch contacts close when the door is
opened.
4. Reinstall the outer case cabinet and check for
microwave leakage around the door with an approved
microwave survey meter. (Refer to Microwave
Measurement Procedure.)
Monitor Switch
Latch
Head
Figure 4-4. Door Switch Components
Latch Hook Left
Secondary
Interlock Switch
Latch Hook Right
Latch
Head
Door
Sensing
Switch
Component Teardown

Door Replacement And Adjustment

DOOR ASSEMBLY REMOVAL
1. Disconnect the oven power supply cord and remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of
the high-voltage capacitor (that is the connecting
lead of the high-voltage rectifier) against the
chassis with the use of an insulated screwdriver.
4. Close the door.
5. Remove the two (2) door springs from the door cam
right, oven hinge right, door com left and oven hinge
left.
6. Release the door cams right and left from the right
and left door cam pins of the door.
7. Remove the door cams right and left from the oven
cavity front plate.
8. Open the door assembly at an angle of more than
90½ degrees to the oven cavity front plate.
9. To release right and left door hinge pins of the door
assembly from the oven hinges right and left, slide
door assembly leftward. When removing the door
assembly, hold door assembly to prevent damage.
When the individual parts are replaced, refer to "Door
Disassembly"
DOOR ASSEMBLY REINSTALLATION
1. On reinstalling the door assembly, insert oven hinges
right and left into the right and left door hinge pins.
2. Insert and hook the door cams right and left to the
right and left door cam pins.
3. Reinstall the two (2) door springs between the door
cams and the oven hinges right and left.
After any service to the door:
(A) Make sure that the door sensing switch and the
secondary interlock switch are operating properly.
(Refer to chapter "Test Procedures".)
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents