Door Replacement

1. Disconnect the power supply cord.
2. Open the door and block it open.
3. Remove the three (3) screws holding the hood
louver to the oven cavity front face plate.
4. Remove the hood louver from the oven cavity by
pushing the right and left tabs of the hood louver.
(Refer to the procedure of "HOOD LOUVER
REMOVAL".)
5. Insert a putty knife (thickness of about 0.5mm)
into the gap A between the door stopper and the
choke cover as shown in Figure C-3 to free
engaging parts.
6. Lift up the door stopper.
7. Now, the door stopper is free from the door
assembly.
8. Lift up the door assembly to release the upper
and lower door hinge pins from the upper and
lower oven hinges.
9. Now, the door assembly is free.
NOTE: When the individual parts are replaced, refer
to "Door Disassembly".
Door Assembly Re-install
1. On re-installing door, insert the lower oven hinge
to lower door hinge pin.
2. Insert the upper oven hinge to the upper door
hinge pin.
3. Shut the door (close the contacts of interlock
switches).
4. Make sure upper and lower oven hinges are
inserted into the upper an lower door hinge pins.
5. Make sure the door is parallel with oven face lines
(left and upper side lines) and door latch heads
pass through latch holes correctly.
6. Re-install the door stopper to the door assembly.
7. Re-install the hood louver to the oven cavity front
face plate with the three (3) screws.
NOTE: After any service to the door:
(A) Make sure that stop switch primary interlock
switch, secondary interlock switch and monitor
switch are operating properly. (Refer to chapter
"Test Procedures".)
(B) An approved microwave survey meter should
be used to assure compliance with proper
microwave radiation emission limitation
standards.
Component Teardown
After any servicing, make sure of the following :
1. Door latch heads smoothly catch latch hook
through latch holes and that latch head goes
through center of latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward
cavity face plate.
4. Re-install outer case and check for microwave
leakage around door with an approved microwave
survey meter.
(Refer to Microwave Measurement Procedure.)
NOTE: The door on a microwave oven is designed to
act as an electronic seal preventing the leakage of
microwave energy from oven cavity during cook cycle.
This function does not require that the door be
air-tight, moisture (condensation)-tight or light-tight.
Therefore, occasional appearance of moisture, light or
sensing of gentle warm air movement around oven
door is not abnormal and do not of themselves
indicate a leakage of microwave energy from oven
cavity.
Upper door hinge pin
Screw
RE-INSTALL
Door assembly
Latch heads
Lower door
hinge pin
RE-INSTALL
Figure C-2. Door Replacement and Adjustment
4-15
Screw
Left tab
Right tab
Hood louver
Upper oven
hinge
Screw
Lower
oven
hinge
Door stopper