1. MOUNTING
1.2

Transceiver Unit

• The transceiver unit generates heat so the mounting location should be well venti-
lated and dry.
• The unit is only designed for bulkhead mounting. The unit weighs 40 kg so reinforce
the mounting location if necessary.
• The length of the cable between the hull unit and the transceiver unit is 5 or 10 m,
and the length of the transducer cable is about 6 m. Determine mounting location
considering these cable lengths.
• Secure the maintenance space shown in the figure below for ease of maintenance
and service.
Fasten the transceiver unit to the mounting location with M10 bolts and nuts.
165
165
1-12
165
689
736
12
13
165
40
425
Transceiver unit, mounting dimensions
200
Cable clamp attached at right side
of unit at default. You can change
the position to left side.