Placing and leveling the range

9 CAUTION
The top edges of the range's side panels must be on
the same or higher level as the adjacent countertop.
DO NOT operate range if sides are lower than the
adjacent cabinet. If the range is operated while at a
lower height relative to the adjacent cabinet, the
cabinet could be exposed to excessive temperatures,
causing damage to the cabinet and countertop.
Leveling leg adjustment
For proper performance, the range must be level. Priority
should be placed on ensuring that the oven cavities are
also level for optimum cooking performance.
1. Measure the countertop heights first with a tape
measure and add an additional 1/16'' - 1/8'' (2-3 mm).
2. Rotate the legs using a 12'' (305 mm) adjustable
wrench on the flat sides of each foot.
Leveling legs should be adjusted so that the range
sides are at the same or higher level as the
adjacent cabinet. Adjust the legs accordingly prior
to pushing the range back to its final location.
It may be necessary to reposition the gas supply
line and the electrical cord as the range is pushed
back to its final position. This may be
accomplished by carefully pulling on a rope or
twine looped around the gas or electrical supply
line as the range is pushed back into its final
installed position.
inches (mm)
3. As the range is moved into its final, installed position,
verify that the anti-tip bracket is in a position to
engage the range.
Adjusting the kick panel
1. Remove the kick panel screws using a T-20 torx
2. Relocate kick panel at one of the five screw hole
3. Repeat with the remaining kick panel screws, assuring

Data rating label

Data rating label
The data rating label shows the model and serial number
of your appliance. The slide-out plate can be accessed by
first removing the kick panel, as shown below.
1/16''-1/8''
(2-3)
Electric wiring diagrams and schematics
The electric wiring diagrams and schematics are attached
behind the toe kick, and should not be removed except by
a service technician, then replaced after service.
screwdriver.
positions, as noted below. Reinstall torx screw.
kick panel is level.
The range kick panel should maintain a minimum
½'' (12.7 mm) clearance above the floor.
Page. 22