Module Specifications; Mechanical Loading; Standards; Fire Class Of Product - Panasonic VBHN330SA17E General Installation Manual

Photovoltaic module
Hide thumbs Also See for VBHN330SA17E:
Table of Contents

Advertisement

MODULE SPECIFICATIONS

Module specifications are shown in
Table 1-1, Table 1-2 and Figure 1.
(Electrical specifications, mechanical
specifications, ENPHASE Microin-
verter IQ7X-96-ACM-US Specifica-
tion, module dimensions)
1)
Rated electrical characteristics are
within the range of –5% to +10% of
the values measured at Standard
Test Conditions (STC). STC condi-
tions are; Irradiance of 1000W/m
25°C cell temperature, AM1.5 and
solar spectral irradiance per IEC
60904-3. Note: At the time of ship-
ment, Panasonic guarantees the
output level of its modules to be -0/
+10% against Rated Power in SPECI-
FICATIONS based on factory inspec-
tion at STC conditions.
2)
Under real conditions, a photovolta-
ic module may experience condi-
tions that produce more current
and/or voltage than reported at
Standard Test Conditions. There-
fore, the Isc value of modules
should be multiplied by a factor of
1.25 to determine ampacity. An
additional factor of 1.25 may be
required for sizing conductors, fus-
es, disconnects, etc. Please refer to
section 690.8 of the National Electric
Code (NEC) for guidelines. The Voc
must be factored according to the
lowest recorded ambient tempera-
ture recorded for the location
where the modules will be installed.
Please refer to section 690.7 of the
NEC for more information regarding
voltage temperature factors.
Electrical Specifications
Model
Cell Number in Series
Rated Power, Watts (Pmax)
Maximum Power Voltage
(Vpm)
Maximum Power Current
(Ipm)
Open Circuit Voltage (Voc)
Short Circuit Current (Isc)
Cell Type
Maximum System Voltage
Factory Installed Bypass
Diodes
Maximum series fuse (A)
VBHN330SA17E is equipped with
Microinverter. Refer to Table 1-2 for
Microinverter specifications.
Microinverters are DC-AC inverters
connected to PV modules in order
to maximize power harvesting by
performing Maximum Power Point
Tracking (MPPT) at the module
level.

MECHANICAL LOADING

2
,
The modules should be mounted at
the four (4) quarter points by the
means shown in Figure 1.
This method offers a maximum load
shown as "Mount Location and
Load Resistance" in Table 1-3 in a
static state on the module surface.
Note: This mechanical loading value
was tested using the mounting de-
vice specified in section "MODULE
INSTALLATION"
As UL Certified Load Ratings, this
module meets design loads as be-
low.
1)
Positive load with Long frame
mounting
・ 33 psf (0-450mm range from edge
・ 75 psf (230-380mm range from edge)
2)
Negative load with Long frame
mounting
・ 33 psf (0-450mm range from edge
・ 61 psf(230-380mm range from edge)
・ 75 psf (230-345mm range from edge)
Table 1-1. Module Specification
Silicon hetero-junction*: Monocrysttaline silicon/amorphous
VBHN330SA17E
96
330
Mechanical Specifications
58.0
Model
5.70
Length, mm (inches)
69.7
6.07
Width, mm (inches)
Silicon hetero-
junction*
Frame Depth,
600
mm (inches)
4
Weight, kg (pounds)
15
3)
・ 33 psf (0-250mm range from edge)
4)
・ 33 psf (0-250mm range from edge)

STANDARDS

VBHN330SA17E comply with the require-
ments of UL1703 (PV module) and UL
1741 (Microinverter, ENPHASE ENERGY,
Inc., Type IQ7X-96-ACM-US

FIRE CLASS OF PRODUCT

silicon hetero-junction
3
Positive load with Short frame
mounting
Negative load with Short frame
mounting
The fire rating of this module is valid
only when mounted in the manner
specified in the mechanical mount-
ing instructions.
The models in this instructions are
suitable to maintain the System Fire
Class Rating A when used with a
Listed mounting system and a roof
covering that have been rated as a
Class A System when installed on a
steep slope roof and/or a low slope
roof with "Type 2" modules.
VBHN330SA17E
1590 (62.60)
1053 (41.46)
40 (1.57)
19.5 (42.99)

Hide quick links: